Use of extraglottic airways in patients undergoing ambulatory laparoscopic surgery without the need for tracheal intubation


Department of Women's Anaesthesia, KK Women's and Children's Hospital, Singapore

Correspondence Address:
T Suhitharan
Department of Women's Anaesthesia, KK Women's and Children's Hospital, 100 Bukit Timah Road
Singapore
Login to access the Email id

Source of Support: T.E. Medical Pte. Ltd. and Intersurgical (Wolkingham, Berkshire, UK). Provided i-gel samples for this study, Conflict of Interest: None


DOI: 10.4103/1658-354X.121081

Rights and Permissions

Background: Second generation extraglottic airway devices with gastric access and separate breathing channels have ushered in a new era where their use is increasingly prevalent in surgical patients who would have been traditionally intubated for general anesthesia. New innovations like the i-gel, which is constructed of a thermoplastic elastomer, provide an airtight seal around patient's perilaryngeal anatomy without the inflatable cuff mechanism found in the laryngeal mask airway supreme (LMAS). Methods: We conducted a randomized controlled trial comparing the LMAS with the i-gel in 70 anesthetized paralyzed patients undergoing laparoscopic female sterilization. Our primary outcome measure was the oropharyngeal leak pressure (OLP). We studied secondary outcomes of successful first attempt insertion rates, time and ease of the airway and gastric tube insertion, leak fractions and pharyngeal morbidity. Results: We found no difference in the OLP between LMAS and i-gel, 25.9 (4.2) versus 24.4 (4.3) s, P=0.153. Both devices had similar first attempt insertion rates (LMAS 94% vs. i-gel 91%) with similar ease and comparable times to achieve an effective airway, LMAS 14.7 (2.7) versus i-gel 16.5 (9.6) s, P=0.306, although gastric tube insertion was easier and faster for the LMAS, 7.9 (1.9) versus i-gel 14.8 (7.7) s, P<0.005. Intraoperatively, there was a significantly greater leak fraction with the i-gel of 0.06 (0.03) versus 0.04 (0.02) with the LMAS, P=0.013. Three patients (8.6%) with LMAS had mild sore throat; one patient (2.9%) had mucosal injury. No complications were documented in the i-gel group. Conclusions: Both these extraglottic airway devices offer similar OLPs, high insertion success rates at the first attempt with similar ease and insertion times (albeit longer gastric tube insertion with i-gel). Both provided effective ventilation despite a higher leak fraction with i-gel that was clinically inconsequential.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed2470    
    Printed89    
    Emailed1    
    PDF Downloaded289    
    Comments [Add]    
    Cited by others 1    

Recommend this journal