Previous article Table of Contents  Next article

LETTER TO EDITOR
Year : 2012  |  Volume : 6  |  Issue : 1  |  Page : 91-92

A modified tracheal tube with curvature-control function for blind nasotracheal intubation


1 Department of Anaesthesiology, Maulana Azad Institute of Dental Sciences, New Delhi, India
2 First Year Dental Student, ATS Dental College, Muradnagar, Uttar Pradesh, India

Correspondence Address:
Manish Naithani
D-126, Surajmal Vihar, Teacher's Colony, Delhi - 110 092
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/1658-354X.93083

Rights and Permissions
Date of Web Publication21-Feb-2012
 


How to cite this article:
Naithani M, Jain A, Deoli A. A modified tracheal tube with curvature-control function for blind nasotracheal intubation. Saudi J Anaesth 2012;6:91-2

How to cite this URL:
Naithani M, Jain A, Deoli A. A modified tracheal tube with curvature-control function for blind nasotracheal intubation. Saudi J Anaesth [serial online] 2012 [cited 2020 Oct 21];6:91-2. Available from: https://www.saudija.org/text.asp?2012/6/1/91/93083

Sir,

Patients with restricted mouth opening are unique challenges in preoperative airway management. In the absence of specialized devices, such as flexible fiber-optic scope, or lighted intubated stylets, and others, blind nasal intubation has been widely practiced for intubating such patients. All blind intubation techniques depend on the operator's skill in manipulating the tip of the tube, and recognizing the alignment with the larynx. Specialized tubes like the Endoflex endotracheal tubes [1] and Endotrol tubes, [2] are extremely useful for oral and nasal intubations, without the need for additional airway adjuncts. We created a similar tube by using an 80 cm long 1-0 silk thread (Ethicon, Johnson and Johnson Company, Somerville, N.J., U.S.A.), which was inserted through the proximal end of the standard polyvinyl chloride cuffed tracheal tube, taken out through the distal end, reinserted into the tube via the murphy eye, and brought out through the proximal end [Figure 1]. Pulling the proximal ends of the thread resulted in decreasing the radius of curvature of the tube, and anterior placement of the tube tip [Figure 2]. We used this modified tracheal tube for blind nasal intubation in 5 adult male patients with restricted mouth opening. Equipment and personnel to deal with an airway mishap were always kept ready. Distance from the tip of the nose to the tragus, and then down till the suprasternal notch (signifying the final depth of tube insertion) was measured for all the patients, and vasoconstrictor drops were instilled in both nostrils. Anesthesia was induced with 4%-6% sevoflurane in oxygen, and the patients were allowed to breathe spontaneously. After adequate depth had been attained, the well-lubricated tube was inserted through the more patent nostril, with the patient's head in sniffing position. A sidestream CO 2 airway adapter was attached to the tube. After pushing the tube beyond the nasopharynx, the curvature was manipulated by pulling on the thread, and the tube advanced toward the larynx, guided continuously by the capnographic waveform on the monitor. After pushing till the desired depth, tube position was reconfirmed by 5-point auscultation. The thread was then removed completely by gently pulling out one of the ends. The tube was fastened, neuromuscular blockade achieved, ventilation commenced, and the surgery was allowed to proceed.
Figure 1: The simple looping of the thread at the tip of the tube, which allows its easy removal after intubation

Click here to view
Figure 2: A prolonged-exposure photograph showing the tube-tip movements on pulling the thread

Click here to view


We found the device convenient to use, and the technique easy to master. The average intubation time (from insertion of the tube through the nostril till confirmation of tracheal position by auscultation and capnography) was 36 s, and was less than 1 min in all the patients. This is acceptable in most clinical scenarios. The problems associated with metal stylets, namely, calculating the bend, their removal, and the risk of trauma, were absent with this technique. The use of the device can safely be extrapolated for oral intubations also. We present the technique for wider appraisal by the esteemed readers.

 
  References Top

1.Yamakage M, Takahashi M, Tachibana N, Takahashi K, Namiki A. Usefulness of endoflex endotracheal tube for oral and nasal tracheal intubations. Eur J Anaesthesiol 2009;26:661-5.  Back to cited text no. 1
[PUBMED]    
2.Asai T. Endotrol tube for blind nasotracheal intubation. Anaesthesia 1996;51:507.  Back to cited text no. 2
[PUBMED]    


    Figures

  [Figure 1], [Figure 2]


This article has been cited by
1 Pyriform Sinus Localization-Assisted Blind Intubation: Comparison with Laryngoscopic Intubation
Shi-yuan Xu
Medical Science Monitor. 2014; 20: 1720
[Pubmed] | [DOI]



 

Top
 
Previous article    Next article
 
  Search
 
    Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
    Access Statistics
    Email Alert *
    Add to My List *
* Registration required (free)  

 
  IN THIS Article
   References
   Article Figures

 Article Access Statistics
    Viewed1945    
    Printed65    
    Emailed1    
    PDF Downloaded135    
    Comments [Add]    
    Cited by others 1    

Recommend this journal