Saudi Journal of Anaesthesia

LETTER TO EDITOR
Year
: 2017  |  Volume : 11  |  Issue : 4  |  Page : 511-

Arm position-dependent kinking of intravenous cannula


Yassar Alamri 
 Brain Research Institute, Department of Neurosciences, Christchurch Public Hospital, Christchurch, New Zealand

Correspondence Address:
Yassar Alamri
Department of Neurosciences and New Zealand Brain Research Institute, 66 Stewart Street, Christchurch Central 8011
New Zealand




How to cite this article:
Alamri Y. Arm position-dependent kinking of intravenous cannula.Saudi J Anaesth 2017;11:511-511


How to cite this URL:
Alamri Y. Arm position-dependent kinking of intravenous cannula. Saudi J Anaesth [serial online] 2017 [cited 2020 Mar 30 ];11:511-511
Available from: http://www.saudija.org/text.asp?2017/11/4/511/215416


Full Text



Sir,

A 60-year-old female sustained a motorbike accident in which she injured her right elbow. Paramedic staff inserted a 14-gauge intravenous cannula (IVC) in her right antecubital fossa, and she was brought to our hospital.

En route, the patient was noted to hold her right arm in elbow flexion which resulted in resistance to intravenous fluid flow.

On arrival at our hospital, the wound was explored and washed; no muscle or tendon injury was noted. The wound was sutured, and an X-ray was obtained to exclude bony injury. The X-ray showed no bony injuries; however, her IVC was noted to be kinked at 90° [Figure 1] and [Figure 2].{Figure 1}{Figure 2}

Her right arm was kept in extension with adequate analgesia; there was no resistance to intravenous fluid flow. The IVC was later removed due to hospital policy of limiting the use of out-of-hospital IVC to 24 h. The patient was discharged 7 days later without clinical sequelae.

Kinking of IVC is a very common occurrence especially in the inpatient population who require ongoing intravenous therapy. While usually a nuisance, complications have been documented in the literature. Forceful application of intravenous therapy against resistance can lead to local tissue trauma and/or extravasation of material.[1] Rarely, a fragment of the IVC may fracture and embolize leading to potentially catastrophic complications.[2] Meticulous care of IVC, including diligent inspection for site infection and minimizing the duration of IVC use, is the standard of care to mitigate such complications.[1]

Financial support and sponsorship

Nil.

Conflicts of interest

There are no conflicts of interest.

References

1Wu CY, Fu JY, Feng PH, Kao TC, Yu SY, Li HJ, et al. Catheter fracture of intravenous ports and its management. World J Surg 2011;35:2403-10.
2Sundriyal D, Jain S, Manjunath S. “Difficult to flush chemoport: An important clinical sign”. Indian J Surg Oncol 2014;5:307-9.