Article Cited by others

ORIGINAL ARTICLE

Comparison of streamlined liner of the pharynx airway (SLIPA TM ) with the laryngeal mask airway Proseal TM for lower abdominal laparoscopic surgeries in paralyzed, anesthetized patients

Abdellatif Ashraf Abualhassan, Ali Monaz Abdulrahman

Year : 2011| Volume: 5| Issue : 3 | Page no: 270-276

   This article has been cited by
 
1 A comparison of the effectiveness of the streamlined liner of pharyngeal airway in paralyzed and nonparalyzed patients undergoing gynecological surgery: a randomized trial
Min Kyoung Kim,Hyun Kang,Geun Joo Choi,Yong Hee Park,Jong In Oh,Chong Wha Baek,Yong Hun Jung,Young Cheol Woo,Yeon Sil Lee
Journal of Clinical Anesthesia. 2016; 34: 327
[Pubmed]  [Google Scholar] [DOI]
2 Preheating of streamlined liner of pharyngeal airway (SLIPA) reduced the related complications: a randomized control study
Guiqi Geng,Yingjie Chen,Hailian Liu
Journal of Clinical Monitoring and Computing. 2016;
[Pubmed]  [Google Scholar] [DOI]
3 Pre-warming the Streamlined Liner of the Pharynx Airway (SLIPA™) improves fitting to the laryngeal structure: a randomized, double-blind study
Hyun Kang,Dong Rim Kim,Yong Hun Jung,Chong Wha Baek,Yong Hee Park,Jong In Oh,Won Joong Kim,Geun Joo Choi
BMC Anesthesiology. 2015; 15(1)
[Pubmed]  [Google Scholar] [DOI]
4 Comparison of streamlined liner of the pharynx airway (SLIPA™) and laryngeal mask airway: a systematic review and meta-analysis
G. J. Choi,H. Kang,C. W. Baek,Y. H. Jung,Y. C. Woo,S. H. Kim,J. G. Kim
Anaesthesia. 2015; 70(5): 613
[Pubmed]  [Google Scholar] [DOI]
5 Comparison of the Disposable Streamlined Liner of the Pharynx Airway and the Disposable I-gel in Anaesthetized, Paralyzed Adults: A Randomized Prospective Study
Khaled EL-Radaideh,Ala"a Alhowary,Diab Bani Hani
Anesthesiology Research and Practice. 2015; 2015: 1
[Pubmed]  [Google Scholar] [DOI]
6 Complications Associated with the Use of Supraglottic Airway Devices in Perioperative Medicine
Pavel Michalek,William Donaldson,Eliska Vobrubova,Marek Hakl
BioMed Research International. 2015; 2015: 1
[Pubmed]  [Google Scholar] [DOI]
7 Gastric Distension With SLIPA Versus LMA ProSeal During Laparoscopic Cholecystectomy
Su Man Cha,Sihyun Park,Hyun Kang,Chong Wha Baek,Yong Hun Jung,Young Joo Cha,Junyong In
Surgical Laparoscopy, Endoscopy & Percutaneous Techniques. 2014; 24(3): 216
[Pubmed]  [Google Scholar] [DOI]
8 Comparative study between LMA-Proseal™ and Air-Q® Blocker for ventilation in adult eye trauma patients
Maha M.I. Youssef,Mona Lofty,Yahya Hammad,Ezzat Elmenshawy
Egyptian Journal of Anaesthesia. 2014;
[Pubmed]  [Google Scholar] [DOI]
9 A comparative study among normal saline, water soluble gel and 2% lidocaine gel as a SLIPA lubricant
Pyung-Gul Park,Geun Joo Choi,Won Joong Kim,So-Young Yang,Hwa-Yong Shin,Hyun Kang,Chong Wha Baek,Yong Hun Jung,Jin-Yun Kim,Min-Su Kang
Korean Journal of Anesthesiology. 2014; 66(2): 105
[Pubmed]  [Google Scholar] [DOI]
10 A comparative evaluation of different supraglottic ventilatory devices during general anesthesia with controlled ventilation: A pilot study
Ahmed A. Abd El Aziz,Elham M. El-Feky
Egyptian Journal of Anaesthesia. 2014; 30(4): 359
[Pubmed]  [Google Scholar] [DOI]
11 Esmolol: A unique beta-blocker in maintaining cardiovascular stability following neurosurgical procedures
Hosseinzadeh, H. and Eydi, M. and Ghaffarlou, M. and Ghabili, K. and Golzari, S.E.J.
Advanced Pharmaceutical Bulletin. 2012; 2(2): 249-252
[Pubmed]  [Google Scholar]
12 A 30 year development of the laryngeal mask. Supraglottic devices without balloon [A 30 años del desarrollo de la máscara laríngea. Dispositivos supraglóticos sin globo]
Carrillo-Esper, R. and Carrillo-CĂłrdova, C.A. and Carrillo-CĂłrdova, D.M. and Carrillo-CĂłrdova, L.D.
Revista Mexicana de Anestesiologia. 2011; 34(4): 313-315
[Pubmed]  [Google Scholar]

 

Read this article