ORIGINAL ARTICLE
Year : 2018  |  Volume : 12  |  Issue : 2  |  Page : 279-282

Lumbar epidural depth using transverse ultrasound scan and its correlation with loss of resistance technique: A prospective observational study in Indian population


1 Department of Anaesthesia, Himalayan Institute of Medical Sciences, Dehradun, Uttarakhand, India
2 Department of aneasthesia, AIIMS, Bhopal, Madhya Pradesh, India

Correspondence Address:
Dr. Rohan Bhatia
Department of Anaesthesia, Himalayan Institute of Medical Sciences, Dehradun, Uttarakhand
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/sja.SJA_679_17

Rights and Permissions

Background and Objectives: The objective of the present study was to evaluate the skin-epidural space distance as assessed by ultrasonography and conventional loss of resistance (LOR) technique and to find the correlation of epidural depth with body mass index (BMI). Methods: Ninety-eight patients of either sex, American Society of Anesthesiology I/II, BMI <30 kg/m2 requiring lumbar epidural for surgery were enrolled. The epidural space was assessed with a curvilinear ultrasound (US) probe, 2–5 MHz, in the transverse plane at L3–L4 intervertebral space. Thereafter, the epidural depth from skin was assessed with conventional LOR method while performing the epidural. The needle depth (ND) was measured using a sterile linear scale, and any change in the needle direction or intervertebral space was noted. Results: The patients were demographically similar. Depth of epidural space measured by US depth (UD) was 3.96 ± 0.44 cm (range 3.18–5.44 cm) and by ND was 4.04 ± 0.52 cm (range 2.7–5.7 cm). The Pearson's correlation coefficient (r) between UD and ND was 0.935 (95% confidence interval: 0.72–0.92, r2 = 0.874, P < 0.001), and Bland–Altman analysis revealed the 95% limits of agreement −0.494–0.652 cm. Conclusion: The present study demonstrates a good correlation between UD and ND and shows that the preprocedural US scan in transverse plane provides accurate needle entry site with a high success rate in single attempt for lumbar epidurals in patients with a BMI <30 kg/m2.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed361    
    Printed11    
    Emailed0    
    PDF Downloaded78    
    Comments [Add]    

Recommend this journal