A case of ingested laryngoscope bulb during emergency endotracheal intubation


Department of Anesthesia, Kasturba Medical College, Manipal, Karnataka, India

Correspondence Address:
Shiyad Muhamed
Department of Anesthesia, Kasturba Medical College, Manipal, Karnataka
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/sja.SJA_10_17

Rights and Permissions
Date of Web Publication27-Mar-2017
 


How to cite this article:
Muhamed S, Mathew S, Rao BM, Arunkumar HD. A case of ingested laryngoscope bulb during emergency endotracheal intubation. Saudi J Anaesth 2017;11:259

How to cite this URL:
Muhamed S, Mathew S, Rao BM, Arunkumar HD. A case of ingested laryngoscope bulb during emergency endotracheal intubation. Saudi J Anaesth [serial online] 2017 [cited 2019 Dec 6];11:259. Available from: http://www.saudija.org/text.asp?2017/11/2/259/203010



Sir,

We report a case of 68-year-old female who presented to emergency department with dyspnea. We decided to intubate in view of decreasing saturation and increased work of breathing. During laryngoscopy, the light of the laryngoscope bulb was not seen clearly and was considered to be due to poor battery quality. The patient was intubated immediately using another laryngoscope. On proper examination of the previous laryngoscope, the bulb was found to be missing. Radiological examination revealed laryngoscope bulb in the stomach of the patient [Figure 1]. Consultation with an experienced gastroenterologist was sought, and an emergency endoscopy was done which failed to retrieve the bulb. Gastroenterologist opined for a conservative management. After 3 days, the laryngoscope bulb was retrieved from the stool of the patient. The patient got discharged after 7 days.
Figure 1: X-ray showing laryngoscope bulb in the stomach

Click here to view


Airway management in critical care is potentially more difficult and more likely to be associated with complications.[1] Few cases have been reported in which the bulb or other part of a laryngoscope was aspirated or swallowed. Ince et al.[2] and Naumovski et al.[3] reported ingestion of laryngoscope bulb in neonates. Thapa et al.[4] reported a case of lost laryngoscope bulb in a neurology patient during endotracheal intubation. Sklar and Tandberg [5] reported a case of ingestion of broken glass of laryngoscope bulb in patient with seizure.

This case is another example among the few existing literature that signifies the importance of proper checking of the integrity of airway equipment both before and after its use. We are fortunate in that the incident was recognized immediately and the laryngoscope bulb was swallowed rather than aspirated. Every effort must be made to find the lost laryngoscope bulb. X-ray of the chest and neck should be taken if the lost bulb cannot be found in the oral cavity. This incident also signifies the importance of the availability of second laryngoscope in cases of emergency intubation.

Financial support and sponsorship

Nil.

Conflicts of interest

There are no conflicts of interest.



 
  References Top

1.
Nolan JP, Kelly FE. Airway challenges in critical care. Anaesthesia 2011;66 Suppl 2:81-92.  Back to cited text no. 1
    
2.
Ince Z, Tugcu D, Coban A. An unusual complication of endotracheal intubation: Ingestion of a laryngoscope bulb. Pediatr Emerg Care 1998;14:275-6.  Back to cited text no. 2
    
3.
Naumovski L, Schaffer K, Fleisher B. Ingestion of a laryngoscope light bulb during delivery room resuscitation. Pediatrics 1991;87:581-2.  Back to cited text no. 3
    
4.
Thapa L, Paudel R, Basnet A, Shilpakar R, Majhi PC, Rana PV. A rolling blackout oral cavity. J Coll Med Sci Nepal 2010;6:44-5.  Back to cited text no. 4
    
5.
Sklar DP, Tandberg D. Glass ingestion from fracture of a laryngoscope bulb. J Emerg Med 1992;10:569-71.  Back to cited text no. 5
    


    Figures

  [Figure 1]



 

Top
 
Previous article    Next article
 
  Search
 
    Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
    Access Statistics
    Email Alert *
    Add to My List *
* Registration required (free)  

 
  IN THIS Article
   References
   Article Figures

 Article Access Statistics
    Viewed1040    
    Printed3    
    Emailed0    
    PDF Downloaded61    
    Comments [Add]    

Recommend this journal