Copper-T, an unusual cause of profuse bleeding during cesarean section


Department of Anaesthesiology and Critical Care, Govt. Medical College and AG Hospitals, Kota, Rajasthan, India

Correspondence Address:
Somvanshi Mukesh
1- JHA-1, Vigyan Nagar, Kota - 324 005, Rajasthan
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/1658-354X.174908

Rights and Permissions
Date of Web Publication2-Jun-2016
 


How to cite this article:
Mukesh S, Archana T, Hemant K. Copper-T, an unusual cause of profuse bleeding during cesarean section. Saudi J Anaesth 2016;10:362-3

How to cite this URL:
Mukesh S, Archana T, Hemant K. Copper-T, an unusual cause of profuse bleeding during cesarean section. Saudi J Anaesth [serial online] 2016 [cited 2019 Oct 20];10:362-3. Available from: http://www.saudija.org/text.asp?2016/10/3/362/174908

Sir,

We present a case of profuse intraoperative bleeding during cesarean section probably caused by a misplaced copper-T perforating the broad ligament.

A 23-year-old healthy woman was scheduled for an emergency cesarean section. She had a copper-T inserted 4 years ago but when she went to the same dispensary for removal of copper-T 2 years ago, she was told that there was no copper-T inside as the intrauterine device (IUD) threads were not visible. Her pressure was 140/80 mmHg and heart rate 100 beats/min, regular. In the operating room, after preoxygenation with 100% oxygen, rapid sequence induction of anesthesia was performed with thiopentone and tracheal intubation was facilitated with suxamethonium. Anesthesia was maintained with nitrous oxide and halothane in oxygen and neuromuscular blocking agent. At delivery, oxytocin 10 units and pethidine 25 mg were given intravenously. During closure of uterine incision, fresh bleeding from the right side of the uterus was noted which on examination did not appear to be from the present uterine incision. Meanwhile, systolic blood pressure decreased to 90 mmHg and heart rate increased to 140 beats/min. Ringer lactate was rapidly infused. On exploration, a large hematoma in the right broad ligament extending up to the retroperitoneal area and a white object protruding out from the posterior aspect of broad ligament were found. This was pulled out and found to be copper-T. Further, a small rent, approximately 2 cm long was seen at the previous uterine scar on the right side. To control the profuse bleeding, the surgeon exposes the right internal iliac artery and ligated it. Once the bleeding was under control, the wound was closed under layers. Meanwhile, 1 unit of fresh whole blood was transfused and the patient's systolic blood pressure improved to 108 mmHg and heart rate 114 beats/min. At the end of surgery, neuromuscular blockade was reversed with neostigmine and atropine and the patient was extubated. The subsequent postoperative course was uneventful.

There is no cause of bleeding from the broad ligament during cesarean section but in our case bleeding occurs due to perforation of broad ligament by misplaced copper-T. The bleeding being profuse and occurring from the unexpected site away from uterine incision led to a delay in its identification and control resulting in hypotension. The management necessitated ligation of the internal iliac artery because the site of bleeding could not be ascertained due to the presence of blood in the operative field. We speculated that the copper-T had perforated the wall of the uterus as evidenced by a small rent on the side and was lying quiescent in the broad ligament. But on manipulation during the cesarean section, it perforated one of the uterine blood vessels which caused bleeding.

IUDs have been reported to perforate neighboring viscera such as rectum, [1],[2] sigmoid colon [3] and the bladder. [4],[5] But perforation of broad ligament presumably due to the intraoperative handling of the tissues leading to profuse bleeding and circulatory disturbance is unknown.

In conclusion, our report serves to highlight some important facts. One should not believe that copper-T may have been expelled spontaneously even if pregnancy occur in a patient who had copper-T inserted which was not removed until and unless the patient herself presents or has seen it on expulsion.

 
  References Top

1.
Zakin D, Stern WZ, Rosenblatt R. Complete and partial uterine perforation and embedding following insertion of intrauterine devices: 1 Classification, complication, mechanism, incidence and missing string. Obstet Gynecol Surv 1981;36:335-53.  Back to cited text no. 1
[PUBMED]    
2.
Eichengreen C, Landwehr H, Goldthwaite L, Tocce K. Rectal perforation with an intrauterine device: A case report. Contraception 2015;91:261-3.  Back to cited text no. 2
    
3.
Browning JJ, Bigrigg MA. Recovery of the intrauterine contraceptive device from the sigmoid colon. Three case reports. Br J Obstet Gynaecol 1988;95:530-2.  Back to cited text no. 3
    
4.
Thomalla JV. Perforation of urinary bladder by intrauterine device. Urology 1986;27:260-4.  Back to cited text no. 4
[PUBMED]    
5.
Sepúlveda WH, Ciuffardi I, Olivari A, Gallegos O. Sonographic diagnosis of bladder perforation by an intrauterine device. A case report. J Reprod Med 1993;38:911-3.  Back to cited text no. 5
    




 

Top
 
Previous article    Next article
 
  Search
 
    Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
    Access Statistics
    Email Alert *
    Add to My List *
* Registration required (free)  

 
  IN THIS Article
   References

 Article Access Statistics
    Viewed1605    
    Printed31    
    Emailed0    
    PDF Downloaded92    
    Comments [Add]    

Recommend this journal