Year : 2014  |  Volume : 8  |  Issue : 1  |  Page : 131-133

Spontaneous migration of central venous catheter tip following extubation


Department of Anesthesia and Critical Care, Belhoul Speciality Hospital, Al Baraha, Deira, Dubai, United Arab Emirates

Correspondence Address:
Balaji Prabaharan
Department of Anesthesia and Critical Care, Belhoul Speciality Hospital, Al Baraha, Deira, P.O. Box: 5527, Dubai
United Arab Emirates
Login to access the Email id


DOI: 10.4103/1658-354X.125975

PMID: 24665255

Get Permissions


Date of Web Publication1-Feb-2014
 

  Abstract 

Migration of the tip of central venous catheters is not an uncommon event and the mechanism for this is not clear. Increased intrathoracic pressure due to coughing, sneezing or weight lifting, changing the body position or physical movements such as abduction or adduction of the arms is thought to be the cause of such migration. We present here a case of a patient with a port catheter tip that migrated from the left subclavian to the superior vene cava following extubation.

Keywords: Central venous catheterization, extubation, migration


How to cite this article:
Prabaharan B, Thomas S. Spontaneous migration of central venous catheter tip following extubation. Saudi J Anaesth 2014;8:131-3

How to cite this URL:
Prabaharan B, Thomas S. Spontaneous migration of central venous catheter tip following extubation. Saudi J Anaesth [serial online] 2014 [cited 2014 Oct 1];8:131-3. Available from: http://www.saudija.org/text.asp?2014/8/1/131/125975


  Introduction Top


Central venous catheterization (CVC) is performed to measure central venous pressure (CVP), which is a simple, relatively inexpensive method of assessing a patient's circulating blood volume, cardiac status and vasomotor tone. It is essential to be aware of the inherent fallacies and inadequacies of the information derived. Inaccurate measurements or inability to obtain an ideal wave form tracing are suggestive of a migration of the catheter tip. Spontaneous migration of CVC tip is reported, but literature on spontaneous migration of CVC tip following extubation is not found. We report a rare spontaneous migration of CVC tip following extubation.


  Case Report Top


We report a case of spontaneous migration of CVC from left subclavian vein (SCV) to the superior vene cava (SVC) following extubation. A 38-year-old 56 kg female with diagnosis of cystadenoma pancreas was scheduled for hemi pancreatectomy. Under all aseptic precautions a 7 Fr triple lumen (arrow international), CVC was inserted in the right SCV and fixed at 12 cm mark and free flow of blood was obtained from the proximal, medial and distal ports and the distal port was connected to the transducer. The CVP tracing was normal, but the measurements remained low that is CVP = 4. Resuscitation with 1 L of normal saline was done. The measurement still did not increase, but the heart rate and blood pressure were stable. Intraoperative the patient remained hemodynamically stable. She was shifted to the intensive care unit (ICU) on the ventilator for elective ventilation and further management.

On chest X-ray, CVC was found crossing the midline (necklace pattern) and seen inside the left SCV [Figure 1]. Since patient was hemodynamically stable and was planned for extubation the next day, removal or redirection of CVC was not done. Chest X-ray performed post-extubation showed CVC in the SVC [Figure 2]. This corresponded to a normal CVP trace also. Then, a good CVP trace was seen in the monitor.
Figure 1: Chest X-ray showing central venous catheter was found crossing the midline (necklace pattern) and seen inside the left subclavian vein. Notice the endotracheal tube in place

Click here to view
Figure 2: Chest X-ray showing central venous catheter in superior vene cava

Click here to view


Since post-operative period was uneventful, CVC was removed on 4 th post-operative day (POD), patient was discharged from ICU to the ward on the 5 th POD and from the hospital 1 week later without any complications.


  Discussion Top


CVC are routinely placed in patients undergoing major surgeries where expected volume and hemodynamic disturbances are likely consequences and/or for multiple infusion administration during surgery or later for parenteral nutrition post-operatively. Anesthesiologists usually place the lines in the operating room pre-operatively and the chest X-ray is done post-operatively to confirm the correct position several hours later. Because incorrect placement can lead to serious complications, which may be categorized as early or late. [1] Early complications include procedural complications directly related to catheter placement, such as hematoma, arterial puncture or injury, venous rupture, pneumothorax, hydrothorax, hemothorax, chylothorax, hydromediastinum, six air embolism, primary malpositioning and catheter transection. Late complications include catheter-related infection, catheter occlusions or thrombosis, catheter fracture and migration. Migrations are rarer than primary malpositionings. [2] Both malpositionings and migrations are often detected by a chest radiograph control. On a chest X-ray, the tip of the CVC should be located to the right side of the midline, ideally just above the level of the right atrium, overlying the anatomical position of SVC. Radiological examinations play an important role in confirming the correct placement of a CVC, confirming the wrong position of a catheter, the repositioning of a misplaced catheter and in retrieving a migrated intraluminal catheter.

Migration of the tip of an intact CVC is not uncommon. Reported sites of migration include the opposite brachiocephalic vein, the jugular vein and the azygous veins. The incidence of spontaneous migration of a port catheter is reported to be about 0.9-1.8%, yet the mechanism of migration is not clear. Malposition of a CVC may occur at the time of insertion or later as a result of spontaneous migration due to anatomic positioning or pressure changes within the thoracic cavity induced by coughing, sneezing, straining or weight lifting. [3] A high infusion flow rate can also make the tip migrate. A case of tip migration after the catheter flushing has been reported. [3] Some authors have reported spontaneous migration of the catheter from the SCV into the ipsilateral jugular vein. [4] Wu et al. [5] reported two cases of implantable port catheter tip migration in patients with severe cough.

Different landmarks, Peres formula (height [cm]/10), right atrial electrocardiogram (ECG) [6] and transesophageal echocardiography also have been used to ensure the correct placement of CVC. In intra-atrial ECG technique, the intra-atrial positioning of the tip of the CVC is detected by the configuration of P wave on ECG, which initially increases in amplitude on advancement and becomes bifid when inside the right atrium and then withdrawn back to get a normal configuration P wave, which indicates optimal position of the tip of the CVC. [7]

So the take home message is that when the central venous waveform could not be obtained despite the change of the transducer, the cable, flushing the unit and repeated zeroing, a strong suspicion of misplacement of CVC to be kept in mind. The ability to aspirate blood freely from the catheter lumen does not necessarily confirm a proper placement. Awareness of this possibility and careful review of the CVC tip position on X-ray pictures in suspicious cases are important. If it is not possible to get chest X-rays with fluoroscopy done immediately or after insertion, then use of intra-atrial ECG technique to ensure correct placement of CVC tip should be done.

 
  References Top

1.Miller JA, Singireddy S, Maldjian P, Baker SR. A reevaluation of the radiographically detectable complications of percutaneous venous access lines inserted by four subcutaneous approaches. Am Surg 1999;65:125-30.  Back to cited text no. 1
    
2.McGee WT, Ackerman BL, Rouben LR, Prasad VM, Bandi V, Mallory DL. Accurate placement of central venous catheters: A prospective, randomized, multicenter trial. Crit Care Med 1993;21:1118-23.  Back to cited text no. 2
    
3.Rasuli P, Hammond DI, Peterkin IR. Spontaneous intrajugular migration of long-term central venous access catheters. Radiology 1992;182:822-4.  Back to cited text no. 3
    
4.Roblin D, Porter JC, Knight RK. Spontaneous migration of totally implanted venous catheter systems from subclavian into jugular veins. Thorax 1994;49:281-2.  Back to cited text no. 4
    
5.Wu PY, Yeh YC, Huang CH, Lau HP, Yeh HM. Spontaneous migration of a Port-a-Cath catheter into ipsilateral jugular vein in two patients with severe cough. Ann Vasc Surg 2005;19:734-6.  Back to cited text no. 5
    
6.Wilson RG, Gaer JA. Right atrial electrocardiography in placement of central venous catheters. Lancet 1988;1:462-3.  Back to cited text no. 6
    
7.Gebhard RE, Szmuk P, Pivalizza EG, Melnikov V, Vogt C, Warters RD. The accuracy of electrocardiogram-controlled central line placement. Anesth Analg 2007;104:65-70.  Back to cited text no. 7
    


    Figures

  [Figure 1], [Figure 2]



 

Top
 
Previous article    Next article
 
  Search
 
    Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
    Access Statistics
    Email Alert *
    Add to My List *
* Registration required (free)  

 
  IN THIS Article
   Abstract
  Introduction
  Case Report
  Discussion
   References
   Article Figures

 Article Access Statistics
    Viewed666    
    Printed6    
    Emailed0    
    PDF Downloaded42    
    Comments [Add]    

Recommend this journal