Sir,

A 52-year-old male patient was scheduled for coronary artery bypass grafting. Patient's echocardiography findings revealed no tricuspid regurgitation or stenosis with good right ventricular function. Preoperatively central venous line was inserted through right internal jugular vein. After insertion, central venous pressure (CVP) waveform showed abnormal large a-c wave complex ([Figure 1] - marked with red arrow) and CVP value was in the range of 10-12 mm Hg. Such wave pattern may resemble a cannon "a" wave of CVP. [1],[2] Transesophageal echocardiography was done which demonstrated lower end of central venous catheter getting abutted with tricuspid valve early in the systole. This explained the mechanism of such abnormal CVP waveform. When central venous catheter was pulled back at the insertion point, CVP waveform showed normal waves and CVP values was in the range of 4-6 mm Hg [Figure 2]. It is important to ascertain the position of central venous line before interpreting waveform.
Figure 1: Abnormal CVP waveform marked with arrow

Click here to view
Figure 2: CVP waveform after pulling central venous catheter

Click here to view


 
  References Top

1.Barbeito A, Mark JB. Arterial and central venous pressure monitoring. Anesthesiol Clin 2006;24:717-35.  Back to cited text no. 1
    
2.Rodes A, Grounds RM, Bennett ED. Hemodynamic monitoring. In: Fink MP, Abraham E, Vincent JL, Kochanek PM, editors. Textbook of Critical Care. 5 th ed. Philadelphia, PA: Elsevier Saunders; 2005. p. 736.  Back to cited text no. 2
    


    Figures

  [Figure 1], [Figure 2]



 

Top
 
Previous article    Next article
 
  Search
 
    Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
    Access Statistics
    Email Alert *
    Add to My List *
* Registration required (free)  

 
  IN THIS Article
   References
   Article Figures

 Article Access Statistics
    Viewed2666    
    Printed20    
    Emailed0    
    PDF Downloaded85    
    Comments [Add]    

Recommend this journal