Unusual difficulty during central venous catheterization


Department of Neuroanesthesiology, Neurosciences Center, All India Institute of Medical Sciences, New Delhi, India

Correspondence Address:
Navdeep Sokhal
Department of Neuroanesthesiology, Neurosciences Center, 7th Floor, All India Institute of Medical Sciences, New Delhi - 110 029
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/1658-354X.93082

Rights and Permissions
Date of Web Publication21-Feb-2012
 


How to cite this article:
Sokhal N, Sokhal S, Chowdhury T. Unusual difficulty during central venous catheterization. Saudi J Anaesth 2012;6:90-1

How to cite this URL:
Sokhal N, Sokhal S, Chowdhury T. Unusual difficulty during central venous catheterization. Saudi J Anaesth [serial online] 2012 [cited 2019 Dec 7];6:90-1. Available from: http://www.saudija.org/text.asp?2012/6/1/90/93082

Sir,

Central venous cannulation and its complications are well described entity in anesthesia. [1],[2] Here we have described an unusual problem encountered during negotiation of guidewire into the side port of introducer needle and its solution that was done in this situation.

We received a call for central venous access in a 26-year-old female patient who was a diagnosed case of tubercular meningitis with very poor peripheral venous access. The patient was on synchronized intermittent mandatory ventilatory support. Coagulation parameters of the patient were in normal range. We decided to cannulate right subclavian vein. We located right subclavian vein using introducer needle in first attempt under all aseptic precautions. But surprisingly we could not negotiate guidewire through the side port of introducer needle even on three attempts. We applied a little force and also tried with different orientations of guidewire assembly. We noticed that guidewire was abutting against the wall of the side port due to angulation of wire inside it [Figure 1]. We removed the needle to check the cause of the same. Guidewire assembly was improperly fitted into side port. We decided to shave off the distal ridge of guidewire holding assembly using scalpel blade of kit [Figure 2]. Now, guidewire could be easily introduced into the needle and we threaded central venous catheter (Certofix Trio V720 7Fr) in the right subclavian vein without any difficulty in our second attempt of cannulation.
Figure 1: (a) Improper fitting of guidewire assembly with gap (horizontal line) and abutting wire tip (black arrow) (b) Perfect fitting after distal ridge shaving and no gap (white arrow)

Click here to view
Figure 2: Before (a) and after (b) shaving distal ridge (After shaving distal ridge diameter is reduced. Compare white arrow with black arrow, in (a) black arrow bigger while in (b) same length.)

Click here to view


Subclavian vein cannulation is associated with multiple complications, including arterial puncture, pneumothorax, hemothorax, and hematoma, which are mostly related to introducer needle. Guidewire-related problems include kinking, knotting, looping, and entrapment of wire in filters, sternocleidomastoid muscle, or even subcutaneous tissue. [3],[4] In our case we were not able to introduce guidewire beyond side port of introducer needle as it was impinging on side wall of the side port. On checking we found that due to some minor manufacturing defect, the distal ridge of guidewire-holding assembly was preventing it from fitting properly inside the side port. The improper fit was creating space for guidewire to follow its natural curve (J tip) and that's why instead of going straight into the needle, the guidewire was abutting against the wall of the side port. Shaving distal ridge made it to fit properly and we catheterized the vein successfully.

Although we do not recommend tempering any medical device, in our condition the cause of problem was obvious and free from any ill effects on the patient. We recommend that before inserting introducer needle one should always check compatibility of the guidewire assembly.

 
  References Top

1.Eisen LA, Narasimhan M, Berger JS, Mayo PH, Rosen MJ, Schneider RF. Mechanical complications of central venous catheters. J Intensive Care Med 2006;21:40-6.  Back to cited text no. 1
[PUBMED]  [FULLTEXT]  
2.McGee DC, Gould MK. Preventing complications of central venous catheterization. N Engl J Med 2003;348:1123-33.  Back to cited text no. 2
[PUBMED]  [FULLTEXT]  
3.Katiyar S, Jain RK. Entrapped central venous catheter guide wire. Indian J Anaesth 2010;54:354-5.  Back to cited text no. 3
[PUBMED]  Medknow Journal  
4.Wang HE, Sweeney TA. Subclavian central venous catheterization complicated by guidewire looping and entrapment. J Emerg Med 1999;17:721-4.  Back to cited text no. 4
[PUBMED]  [FULLTEXT]  


    Figures

  [Figure 1], [Figure 2]



 

Top
 
Previous article    Next article
 
  Search
 
    Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
    Access Statistics
    Email Alert *
    Add to My List *
* Registration required (free)  

 
  IN THIS Article
   References
   Article Figures

 Article Access Statistics
    Viewed1371    
    Printed134    
    Emailed0    
    PDF Downloaded116    
    Comments [Add]    

Recommend this journal